POWER SYSTEMS / CRPS SERVER PSU
Titanium conversion, hot-swap by design.
CRPS and mCRPS server PSUs from 550W to 5.5kW+ — 80 PLUS Titanium efficiency, 54V rails for GPU racks, and a burn-in room every unit passes before it ships.
SPEC SHEET
| Form factor | CRPS 73.5×40×185 / 265mm · mCRPS |
|---|---|
| Power range | 550W – 3200W standard · 5.5kW+ AI class |
| Output | 12V main · 54V AI rail · +5Vsb standby |
| Efficiency | 80 PLUS Titanium · 96% @50% load (230V) |
| Control | PMBus digital · firmware telemetry |
| Redundancy | N+N / N+1 hot-swap |
| Safety | UL 62368-1 · IEC 62368-1 · CE/UKCA |

WHY 54V
One less conversion on the way to the GPU.
Legacy 12V architectures step down twice between the PSU and a modern accelerator. A 54V direct-to-rail feed skips a stage, carries roughly four times the power per conductor, and frees floor space for compute instead of copper. That is why the GB300 generation of AI racks standardized on high-current 54V shelves — and why our roadmap follows the mCRPS footprint TI and shelf vendors are converging on.
STANDARD RANGE
Wattage ladder, OEM-tunable.
Every row below is a platform, not a fixed SKU — fan curves, connector sets and faceplates are configured per program.
| Model class | Power | Output | Efficiency | Cooling | Typical use |
|---|---|---|---|---|---|
| CRPS-S | 550–800W | 12V | Platinum / Titanium | 40mm fan | Storage & edge servers |
| CRPS-M | 1300–1600W | 12V | Titanium | 40mm fan | 1U/2U compute |
| CRPS-L | 2000–3200W | 12V / 54V | Titanium 96% | Centrifugal blower | AI nodes · NVL-class trays |
| mCRPS | 3600W+ | 54V | Titanium | Modular fan wall | High-density GPU shelves |
| CRPS-AI | 5500W+ | 54V multi-rail | Titanium target | Blower + cold-plate option | GB300-class power shelves |
| Shelf system | up to 33kW | 54V busbar | System-managed | Shelf fans + BBU bay | Complete rack power shelf |
PRODUCTION PATH
Every unit through the same gates.
SMT & DIP
Power stages placed on dedicated high-current lines with SPI paste checks and AOI after reflow.
Auto test
Hi-pot, ground bond, in-circuit and functional stations log every serial to the unit record.
100% burn-in
Full-load aging room cycles at elevated temperature; zero-defect exit criteria per lot.
Compliance pack
UL 62368-1 evidence, 80 PLUS style reports and export docs assembled per destination market.

OEM / ODM OPTIONS
Configured to your chassis, not ours.
Connector families, faceplate silk, fan curves, PMBus maps and packing are all program parameters. Typical OEM engagements start from a chassis drawing and end with a shelf-ready kit — including matching power shelves and BBU bays from our integration line.
FAQ
CRPS questions we hear most.
What does the CRPS form factor actually standardize?
Why is 54V output becoming the AI standard?
What does 80 PLUS Titanium guarantee?
Can you match our existing shelf firmware polling?